welcome To Shijiazhuang Dekun Technology Co., Ltd. Official website!
Language: 中文版 ∷  英文版

Process control instrumentation

  • DK2800 series PID program curve control instrument

DK2800 series PID program curve control instrument

  • The 2800 Series Program Process Controller is an industrial process control instrument designed with the latest measurement control technology. Advanced hardware and software design techniques with high measurement and control accuracy.

    Support 9 process curves, each can set 24 segment program curve, can realize process control of 24 segment curve, can realize relay action output, 5 groups PID call and other practical functions in 24 segment curve according to need. Achieve complex requirements for curve process control.

    The program process controller has dual heating and cooling output control functions, and the second input oxygen sensor sensor can realize the carbon potential control function in the heat treatment application.

    The second auxiliary input channel has a heater disconnection alarm function, a remote DCS remote control setting set value SV, and an oxygen probe input carbon potential control function. Support high-low temperature switching function of dual input sensor.

    Switching optical input is divided into 2 groups, which can realize flexible application switching of various application functions.

    The process controller has 47 industrial signal sensor input functions.

    Control output types are: relay, analog linear signal, solid state relay output (transistor), thyristor (can directly drive electrical equipment below 5 amps).

    The program controller has a very convenient man-machine dialogue interface design, and the button operation is simple and convenient. Functions such as the current remaining time and the current set value can be prompted when the program curve is executed.

    The program curve local editing input is simple and convenient, the block curve has the power-down data retention function, and the power-on alarm exemption function.

    Support packet PID limiting function. Advanced control algorithms are used to adapt to various operating conditions.


  • Online orders

Features

True color IPS TFT full-view liquid crystal display, alarm status color change prompt

Standard MODBUS RTU communication

Support 9 process curves, each can set 24 segment program curve

Group PID, suitable for various characteristic loads

Remote analog setting, communication control, heater disconnection protection, etc.

Support PT1000 input, industrial oxygen probe carbon potential control

Improved DK PID algorithm for more precise control

With sensor feed power supply, anti-jamming design

Input

K

S

R

T

E

J

B

N

WRe3-WRe25

WRe5-WRe26

Cu50

Pt100

Pt500

Pt1000

0 to 80 Ω

0 to 400 Ω

0 to 4000 Ω

0 to 10 mA

0~20mA

4~20mA

0 to 20 mV

0 to 100 mV

-20~+20mV

-100~+100mV

0 to 1V

0~2V

0 to 5V

1 to 5V

0 to 10V

2 to 10V

-5V to +5V

-10V~+10V

Cu10

Cu100

Pt10

Pt50

Pt200

JPT10

JPT50

JPT100

JPT200

JPT500

JPT1000

Ni100

Ni200

Ni500

Ni1000

Output

Master output:

4-20MA

0-20MA

0-10MA

Relay output

Transistor solid state output

Thyristor output

Transmitting output:

4-20MA,

0-20MA,

0-10MA

communication

Standard Modbus RTU communication protocol

Alarm

2-way relay alarm output

Up to 4 channels.

Other detailed parameters

1. Control cycle: 50mS/100mS

2. Measurement accuracy: 0.1% FS (using 24-bit AD)

3. Sample rate: 20Hz/10Hz

4. Control output:

    Analog signal: 4-20MA, 0-20MA (<500Ω), 0-10MA (<1kΩ)

    Relay: 2A (250V AC)

    Solid state relay (transistor): 22V 20MA

    Thyristor: 6A 250V AC

5. LED digital tube: three rows display

    The first row of PV 5, the second row of SV 5, the third row of information 3

6. Signal measurement input impedance: voltage ≥ 500KΩ (5V, 10V ≥ 100KΩ), current ≤ 120Ω,

    Thermocouple ≥500KΩ

7. The resistance is measured by three-wire system, and the resistance of each line of the signal transmission 

wire is not more than 10 ohms.

8. Standard MODBUS RTU communication protocol. Two-wire RS485

    Calibration method: no parity, odd parity, even parity

      Communication speed: 4800BPS, 9600BPS, 19200BPS

      Address range: 1~247

9. Equipment power supply: 86~260V AC (47~63HZ)

10. Isolation voltage: input, output, power supply isolation voltage 2300V AC / 1MIN

11. Operating temperature: 0~50°C

12. Storage conditions: temperature -40 ° C ~ 80 ° C; humidity 10% ~ 90% RH

1 3. Dimensions: 96*96mm (opening size 92*92mm), 96*48mm (opening size 92*44mm)

14.EMC standard: EN61326*

15. Safety standards: EN61010 and UL3121

16. Protection level: IP66

17. Power consumption: 7W

Selection size

96*96mm (opening size 92*92mm),

96*48mm (opening size 92*44mm)

48*96mm (opening size 44*92mm)

Selection example

The customer needs to measure and collect 1 K-type thermocouple signal, 1 B-type thermocouple signal, with 2 

alarm outputs, with communication.

The main control outputs 2 channels of 4-20MA signals, and outputs 4-20MA signals. The opening size is required 

to be 92*92mm.

The selection code is:

DK2804-K-B-4MA20-4MA20-4MA20-R-R-S